£6,228.38 excl. VAT
£7,474.06 inc. VAT
From now on, all Memmert HCP humidity chambers are available with the TwinDISPLAY convenience features as standard. A compact 56 litre benchtop model complements the humidity chamber range, first presented at Control 2018 in Stuttgart.
Extensive comfort functions
This high-quality climate chamber is an economical and almost maintenance-free alternative to appliances with active cooling, especially for applications above room temperature such as accelerated service life tests and 85/85 tests. The ControlCOCKPIT touch screen control unit is the HCP's control centre, where all parameters can be set in three quick steps. Status messages as well as time and alarm messages are also displayed simultaneously. The TwinDISPLAY convenience features also allow communication via modern interfaces and intuitive and simple programming via the control and protocol software AtmoCONTROL. Specially adapted functions such as battery-buffered operating display, SetpointWAIT function for temperature-dependent process runtime, alarm messages via e-mail or SMS and standard feed-throughs on the rear panel support reliable and precise testing processes.
Active humidity control minimises condensation
Like all Memmert climate chambers that operate in the positive temperature range, the humidity chamber HCP also has active humidity control. It guarantees reliable homogeneity of temperature and humidity as well as short recovery times after opening the door. In combination with heating on all six sides, including heated inner glass door, it minimises vaporisation in the interior and thus the risk of condensed water dripping onto the test object.
We want the process of purchasing a test chamber to be as simple as possible. Below we provide some extra information and links to our specific guides.
What is a test chamber? A test chamber is used to simulate environmental conditions and this can be used in many applications including stability testing in a range of industry types. But how exactly is it different to a humidity chamber or an incubator? Can these units be certified medical devices? Can they perform testing in accordance with any recognised standards? What water supply is needed for a humidity chamber? If you want to know this and more including answers to an array of our most asked questions click here. |
Choosing the right test chamber Choosing the right test chamber for your application can be a bit of a minefield, with such a large selection available from our supplied brands Memmert and MMM Medcentre. Here we list the differences between chamber ranges such as what exactly the different controller types are and how this impacts use and other points to consider when selecting the most suitable chamber. |
Caring for your test chamber Test chambers are a costly purchase so you will want to keep it in top shape. You should be wiping down the chamber inside and out and be careful with how you load it to ensure efficient operation. If you want to know what else you should do to maintain your chamber and actions to follow to keep it working at its best then you can check out this page. |
If you require any further assistance, or extra information you can request that here and one of our trained technical specialists will be in contact. Please provide as much detail as possible so that we can get back to you with the right information.
Camlab offer a very wide range of calibration and validation options for your Memmert chamber. We can provide these services to all Memmert chambers even if purchased via a third party.
Validation of your new Memmert Chamber
Calibration services (single point at up to 3 temperature / humidity values)
Camlab can calibrate your chamber at up to 3 different temperatures and/or humidity values of your choice either prior to delivery at the Camlab Cambridge site or after delivery at your facility (receive significant discounts when this is done at the Camlab Cambridge site).
The unit is calibrated when the probe is placed in the middle of the chamber (single point calibration).
Installation Qualification (IQ) services for new Memmert chambers
This covers basic initial checks of the packaging, documents, software, ancillaries, damage, ambient readings and basic training. IQ services are provided free when purchasing the OQ services from Camlab.
When IQ is performed at the Camlab Cambridge site prior to delivery, this will exclude measuring ambient temperatures and the checking of local power supplies. Training will be supplied via remote live web based connection.
Operational Qualification (OQ) services for new Memmert chambers
This covers checking the display functions, fan control, USB port (Memmert plus units only), temperature and humidity control, over temperature alarms, and full temperature mapping.
Temperature mapping is carried out at either 9 points (small chambers) or 27 points (larger chambers). Temperature mapping is carried out at temperature and humidity settings of your choice. OQ generally takes a minimum of 1 day to complete.
OQ can be completed either prior to delivery at the Camlab Cambridge site or after delivery at your facility (receive significant discounts when this is done at the Camlab Cambridge site).
Please note 3 grid style shelves are required to fully complete the OQ temperature mapping
Performance Qualification (PQ) services for new and existing Memmert chambers
This covers the temperature mapping of your chamber once it is loaded with your product. The probes are placed in as near to their normal location as is possible. The PQ process does not include optimization but it can be repeated up to 3 times.
Temperature mapping including calibration of your existing Memmert chambers
This covers the temperature mapping of your existing chamber. Temperature mapping is carried out at either 9 points (small chambers) or 27 points (larger chambers). Temperature mapping is carried out at temperature and humidity settings of your choice.
Camlab can carry out the temperature mapping in 2 alternative ways:
Training
Camlab provide free basic user training with every chamber. This free training is provided via remote live web based connection.
For detailed quotations and validation enquiries please call 01954 233110 or email sales@camlab.co.uk
Basic Warranty
Your brand new Memmert chamber is delivered with a manufacturers backed 36 months parts only warranty. To support this and provide you full peace of mind in the first year, Camlab also provide a 12 months labour warranty free of charge. This means that should there be a fault in the first 12 months from delivery of your Memmert chamber, Camlab will fix this free of charge (exclusions apply).
Free Training
Camlab provide free basic user training with every Memmert chamber purchased from Camlab. This free training is provided via remote live web based connection.
Option: Extend your labour warranty to 36 months
With the exclusive Camlab “Memmert Extended” Warranty option, you can extend your Camlab labour warranty from 12 months to 36 months. Camlab would then fix any qualifying fault free of charge in the first 36 months from delivery.
Option: Extend your labour warranty and include 1 calibration / maintenance visit
With the exclusive Camlab “Memmert Standard” Warranty option, you can extend your Camlab labour warranty from 12 months to 36 months. Camlab would then fix any qualifying fault free of charge in the first 36 months from delivery.
This also includes a single calibration / maintenance visit by a Camlab engineer at a time of your choosing within the 36 months period.
Option: Extend your labour warranty and include an annual calibration / maintenance visit
With the exclusive Camlab “Memmert Standard” Warranty option, you can extend your Camlab labour warranty from 12 months to 36 months. Camlab would then fix any qualifying fault free of charge in the first 36 months from delivery.
This also includes a calibration / maintenance visit by a Camlab engineer every year during the 36 months period. This is the most comprehensive support package available for Memmert units anywhere in the UK.
Temperature mapping including calibration of your existing Memmert chambers
This covers the temperature mapping of your existing chamber. Temperature mapping is carried out at either 9 points (small chambers) or 27 points (larger chambers). Temperature mapping is carried out at temperature and humidity settings of your choice.
Camlab can carry out the temperature mapping in 2 alternative ways:
For detailed quotations and validation enquiries please call 01954 233110 or email sales@camlab.co.uk
For more information on this product please click the Request information button below and we will get back to you as soon as we can.
|
This link will take you to an external site. Please provide as much detail as possible so that we can get back to you with the right information.
|
A consultation visit from one of highly experienced product specialists is available for this range. Typically our specialist will be able to go through the following aspects with you to help you make the right choices and be able to deliver them on time and and on budget.
Please click the Request Consultation button below and we will get back to you as soon as we can. |
This link will take you to an external lead collection site. Please provide as much detail as possible so that we can get the right specialist to conatact you. |