Simplify complex titration with the Titralab AT1000 from Hach. Straight from the box the AT1000 eliminates operator interpretation and manual processes you have come to expect with existing manual titration. The automatic system gives you more reliable results without complicated analysis. To make setup and titration simple, the AT1000 utilises application specific kits to make it quick and easy for anyone to set up and operate a test. - Reliable titration results - Simple setup and titration.
This set up required Application Package/s: AP0005.AT1222 pH, Alkalinity & Hardness in Water, AP0011.AT1222 pH, Total Acidity & Chlorides in Food & Beverage, AP0013.AT1222 pH, Total Acidity, Free & Total SO‚‚ in Wine
A Titralab 1000 Series system is composed of two elements: The Application Package and the Titrator (AT1000 or KF1000). The Titrator is delivered preassembled for quick setup, and the application package includes all specific elements to make it quick and easy for anyone to set up and operate a test without need for any complex programming. By providing automatic titrations that reduce testing complexity, the Titralab AT1000 Series increase confidence in results and eliminates operator interpretation commonly associated with manual titration.
Simple setup and titration Application-specific functions set per titrator to eliminate complex titration setup and analysis. HACH LANGE's unique application kits make it quick for anyone to set up and operate a test. Please note: these application packs must be purchased along with the titrator.
Application: 10
Automatic reagent addition: Integrated peristaltic pumps for reagent addition
Beaker volumes accepted: System specific beakers: Polypropylene, 50 mL & 150 mL with clips
Generic beakers supported: Up to 250 mL low form glass
Burette for Titrant: 2
Burette motor resolution: 20,000 steps with electronic µstepping technology (128 µsteps/step)
Operating temperature range: 15 - 35 °C (59 - 95 °F)
Output: Electrode ports (x2), USB (x2), Serial (x1), Ethernet (x1)
Parameter: mV/pH, Conductivity, Temperature (°C or °F)
Password protection: Yes, user defined protected elements
Pollution degree: 2
Power requirements (Hz): 50/60 Hz
Power requirements (Voltage): 100/240 V AC
Pump flow rate: 100 mL/min
Pumps: 2
Required Application Package/s: AP0005.AT1222 pH, Alkalinity & Hardness in Water, AP0011.AT1222 pH, Total Acidity & Chlorides in Food & Beverage, AP0013.AT1222 pH, Total Acidity, Free & Total SO‚‚ in Wine
Resolution: Conductivity: ±0.5 % of reading mV/pH: ±0.1 mV / ±0.001 pHv Temperature: ±0.3 °C
Sample stand: Integrated, magnetic stirring, beakers up to 250 mL
Application Packages for use with Titralab 1000 Series titrators from Hach contain all elements except reagents to make it quick and easy for everyone to set up and operate a test. Each Application Package is specifically designed for unique parameters to ensure accurate and reproducible measurements at a glance, including*:
Adapters
Glass bottle
Magnetic stirring bars
Polypropylene beakers
Bottle stopper with desiccant tube
Electrode(s) (Digital Intellical or Analogue)
High precision glass syringe (Hamilton)
USB key containing application notes and applications to automatically program titrators for selected parameters.
Setting up your application has never been so simple.
* Application package content varies depending on application/parameters.
Part Number
Application
Parameter
Compatible instruments
Type
AP0001.AT1102
Municipal Applications
pH/Alkalinity
AT1102 AT1112 AT1122 AT1222
Application Pack
AP0006.AT1102
Environmental Applications
FOS/TAK (Biogas)
AT1102 AT1112 AT1122 AT1222
Application Pack
AP0025.AT1102
Food & Beverage
pH, Total Acidity
AT1102 AT1112 AT1122 AT1222
Application Pack
AP0026.AT1222
Food & Beverage
pH, Total Acidity
AT1222
Application Pack
AP0002.AT1102
Municipal Applications
pH/Alkalinity & Conductivity
AT1102 AT1112 AT1122 AT1222
Application Pack
AP0003.AT1112
Municipal Applications
Ca & Mg Hardness (ISE)
AT1112 AT1122 AT1222
Application Pack
AP0004.AT1112
Municipal Applications
Total Hardness (Color)
AT1112 AT1122 AT1222
Application Pack
AP0005.AT1222
Municipal Applications
pH/Alkalinity & Hardness
AT1222
Application Pack
AP0007.AT1122
Municipal Applications
Free & Total Chlorine, Chlorine Dioxide, Chlorite, Sulfite (Autocat)
AP0001.AT1102 pH & Alkalinity in Water AP0006.AT1102 Volatile Acids & Alkalinity (Biogas) AP0008.AT1102 pH & Total Acidity in Wine & Juices AP0015.AT1102 TAN AP0016.AT1102 TBN
AP0001.AT1102 pH & Alkalinity in Water AP0006.AT1102 Volatile Acids & Alkalinity (Biogas) AP0008.AT1102 pH & Total Acidity in Wine & Juices AP0015.AT1102 TAN AP0016.AT1102 TBN
AP0005.AT1222 pH, Alkalinity & Hardness in Water AP0011.AT1222 pH, Total Acidity & Chlorides in Food & Beverage AP0013.AT1222 pH, Total Acidity, Free & Total SO₂ in Wine
KF1121.82
For Titrant 1
2
Volumetric Karl Fischer, AC or DC imposed current
AP0014.KF1121 Moisture Content
KF1121.98
For Titrant 1
2
Volumetric Karl Fischer, AC or DC imposed current
AP0014.KF1121 Moisture Content
Hach Claros Collect software - Accurate field data collection made simple – part of Claros- The Water Intelligence System.
Claros Collect allows you to use your web enabled devices to manually enter data. It validates your data at the source of collection by triggering alerts when values are outside an expected range. Claros Collect eliminates the need for manual paper forms. Once data is entered, it is immediately available to everyone - reducing transcription errors and time spent waiting for data. This enables teams in the field and in the office to be aware of potential water quality changes immediately and make decisions faster with instant data availability.
Data can be collected whether a network is available or not. In the event of non connectivity, data collected from the field is saved on the device until a connection is available and data is synced and consolidated in the central Claros database.
Access your data anytime, anywhere from a variety of devices, including a smart phone, tablet or computer. All data is consolidated, organized and available for immediate analysis via spreadsheets and graphs.
Add and review lab and field data. Claros Mobile Sensor Management (MSM) customers can also compare and trend process values with their lab and field data
Further informaiton on Claros can be found in the following documents:
Hach Claros Collect software is part of Claros - The Water Intelligence System.
Claros Collect will turn your data into powerful operational insights. Eliminate uncertainty, increase confidence. Welcome to the Power of Claros.
For very small plants: population equivalent < 10.000 (< 600 kg/d BSB5)
Manually enter data in the field, from any mobile and web enable device
Data is validated at the source of collection
Data is saved, synced and consolidated in the central Claros database
View data in spreadsheets and graphsHach Claros Collect software is part of Claros
For medium plants - population equivalent > 50.000 and <100.000 (>3.000 and < 6.000 kg/d BSB5)
Manually enter data in the field, from any mobile and web enable device
Data is validated at the source of collection
Data is saved, synced and consolidated in the central Claros database
View data in spreadsheets and graphs
For large plants - population equivalent > 100.000 and < 300.000 (>6000 and < 18.000 kg/d BSB5)
Manually enter data in the field, from any mobile and web enable device
Data is validated at the source of collection
Data is saved, synced and consolidated in the central Claros database
View data in spreadsheets and graphs
For very small water plants size. Collect data in the field once, on any web enable device, validate, sync and consolidate it on the central Claros database. With Collect, teams are aware of potential water quality changes instantly.
For medium water plants size. Collect data in the field once, on any web enable device, validate, sync and consolidate it on the central Claros database. With Collect, teams are aware of potential water quality changes instantly.
For large water plants size. Collect data in the field once, on any web enable device, validate, sync and consolidate it on the central Claros database. With Collect, teams are aware of potential water quality changes instantly.
Requirements
Mobile iOS Download the app CLAROS COLLECT from the App store Requires iOS 11.0 or greater
Mobile Android Download the app CLAROS COLLECT from Google Play Requires Android 5.0 or greater
Compatibility With any mobile device with a supported web browser
Web Browsers Current and previous release of Google Chrome, Safari, and Microsoft Edge desktop browsers.
Video Help Using Claros
Claros Collect Basic Functions
Claros Collect Username Recover
Claros Password Recovery
Claros Mobile Sensor Management How To Calibrate an LDO2 Sensor
Claros Mobile Sensor Management How To Trigger a Maintenance Workflow
Claros Mobile Sensor Management How To Configure Milliamp Outputs
Claros Mobile Sensor Management How to Download Data
Mobile Sensor Management How to Configure the Modem on the Hach SC4200c Controller
For more information on this product please click the Request information button below and we will get back to you as soon as we can.
Alternatively, a consultation visit from one of our highly experienced product specialists is available for this range. Typically our specialist will be able to go through the following aspects with you to help you make the right choices and be able to deliver them on time and and on budget.
Your product or service requirements
Performance criteria
Budget constraints
Site access
Project timeframes
Services available
Environmental factors
Please click the Request Consultation button below and we will get back to you as soon as we can.
The links above will take you to our request information page which will forward your enquiry to our team. Please provide as much detail as possible so that we can get back to you with the right information. We normally aim to get back to you same day or within 24 hours on weekdays. If you enquiry is more urgent please call our support team on 01954 233 120
The FOS/TAC ratio is a commonly used indicator for assessing the fermentation process within biogas reactors, where FOS is a measure of the volatile organic acids (measured in mg CH3COOH/l) and is TAC is a measure of the total inorganic carbon i.e. the alkaline buffer capacity of the system (measured in mg CaCO3/l). In simple terms, this ratio looks at acid vs alkaline in the system which helps...
Burkle's very popular automatic burettes are now available in a plastic coated version - making them shatter and splinter proof. [caption id="attachment_7521" align="aligncenter" width="225"] The Automatic Burette offers a quick and easy way to perform manual titrations, and is now available in a plastic coated version[/caption] Due to their delicate construction and shape, traditiona...