NANOCOLOR STANDARD TESTS

Macherey-Nagel For the highest sensitivity and accuracy. The use of rectangular cuvettes with 50 mm optical path allows the detection of least amounts of the detectable substance. The use of a large sample volume guarantees safe and reproducible results.
pic
ProductsDescription

NANOCOLOR Standard test Fluoride

Picture of NANOCOLOR Standard test Fluoride
1187636
918142
MN/918142

£82.94 (exc. VAT)
£99.53 (inc. VAT)
Qty
Order now for 7 day delivery
DescriptionMediaReviews
Photometric determination of fluoride with 1,8-dihydroxy-2- (4-sulfophenylazo) naphthalene-3,6-disulfonic acid (SPADNS).

New 
  • Shortened reaction time from 5 to 1 minute
  • No aluminum sealing

Data
  • REF918142
  • Typestandard test 1-42
  • Range0.05 - 2.00 mg/L F-
  • Sufficient for500 determinations
  • Shelf life2 years
  • Sea water suitability: yes

* * Please see leaflet

NANOCOLOR Standard test Iron

Picture of NANOCOLOR Standard test Iron
1178172
91836
MN/91836

£120.33 (exc. VAT)
£144.40 (inc. VAT)
Qty
Order now for 7 day delivery
DescriptionSpecificationsMediaReviews
Photometric determination with 1,10-phenanthroline.
Iron(II) ions react with 1,10-phenanthroline to from an orange colour complex. This method determines dissolved and easily soluble iron compounds.

Data:
  • Cat. No.918 36
  • Typestandard test 1-36
  • Range10 mm cuvette: 0.1 - 15.0 mg/l Fe 50 mm cuvette: 0.01 - 2.00 mg/l Fe
  • Sufficient for250 determinations
  • Shelf lifeat least 3 years
  • Sea water suitability: yes

NANOCOLOR Standard test Ammonium

Picture of NANOCOLOR Standard test Ammonium
1178173
91805
MN/91805

£117.61 (exc. VAT)
£141.13 (inc. VAT)
Qty
Order now for 7 day delivery
DescriptionSpecificationsMediaReviews

Photometric determination with eriochrome cyanine R.

In weakly acidic solution aluminum ions react with eriochrome cyanine R to form a red-violet coloured complex.

Data
  • REF918 02
  • Type: standard test 1-02
  • Range0.01 - 1.00 mg/L Al3+
  • Sufficient for250 determinations*
  • Shelf life2 years
  • Sea water suitability: yes**

* Maximum number, the actual number of tests depends on the sample volume
** Please read the leaflet

NANOCOLOR Standard test Nitrate range:0.1 - 30.0 mg/L NO3-N 4 - 140 mg/L NO3-

Picture of NANOCOLOR Standard test Nitrate range:0.1 - 30.0 mg/L NO3-N 4 - 140 mg/L NO3-
1178174
91865
MN/91865

£101.16 (exc. VAT)
£121.39 (inc. VAT)
Qty
Order now for 7 day delivery
DescriptionSpecificationsMediaReviews
Photometric determination with 2,6-dimethylphenol in sulphuric acid / phosphoric acid mixture.
In acidic solution, nitrate ions react with 2,6-dimethylphenol to form 4-nitro-2,6-dimethylphenol, which can be evaluated photometrically.

Data
  • REF91865
  • Typestandard test 1-65
  • Range0.1 - 30.0 mg/L NO3-N 4 - 140 mg/L NO3-
  • Sufficient for100 determinations
  • Shelf life2 years
  • Sea water suitability: no

NANOCOLOR Standard test Nitrite

Picture of NANOCOLOR Standard test Nitrite
1178175
91867
MN/91867

£87.02 (exc. VAT)
£104.42 (inc. VAT)
Qty
Order now for 7 day delivery
DescriptionSpecificationsMediaReviews
Photometric determination with sulphanilic acid and 1-naphthylamine.
In acidic solution sulphanilic acid is diazotised with nitrite. The diazonium salt is coupled with 1-naphthylamine to form a red dye.

Data
  • Cat. No.918 67
  • Typestandard test 1-67
  • Range10 mm cuvette: 0.01 - 0.30 mg/l NO2-N / 0.10 - 1.00 mg/l NO2- 50 mm cuvette: 0.002 - 0.100 NO2-N / 0.005 - 0.250 NO2-
  • Sufficient for220 determinations
  • Shelf lifeat least 18 months
  • Sea water suitability: yes

NANOCOLOR Standard test Copper

Picture of NANOCOLOR Standard test Copper
1178176
91853
MN/91853

£124.54 (exc. VAT)
£149.45 (inc. VAT)
Qty
Order now for 10 day delivery
DescriptionMediaReviews
Photometric determination with cuprizone (oxalic acid bis-cyclohexylidene hydrazide).
In weakly alkaline solution copper(II) ions react with cuprizone [oxalic acid bis(cyclohexylidene hydrazide)] to form a blue complex.

Data
  • Cat. No.918 53
  • Typestandard test 1-53
  • Range10 mm cuvette: 0.1 - 10.0 mg/l Cu2+ 50 mm cuvette: 0.01 - 2.00 mg/l Cu2+
  • Sufficient for250 determinations
  • Shelf lifeat least 2 years
  • Sea water suitability: yes

NANOCOLOR Standard test Zinc

Picture of NANOCOLOR Standard test Zinc
1178177
91895
MN/91895

£158.27 (exc. VAT)
£189.92 (inc. VAT)
Qty
Order now for 7 day delivery
DescriptionMediaReviews
Photometric determination with zincon At pH 10.5–11.5 zinc ions react with zincon to form a blue color complex.

Data
  • REF918 95
  • Typestandard test 1-95
  • Range10 mm cuvette: 0.1 - 3.0 mg/L Zn2+ 50 mm cuvette: 0.02 - 1.50 mg/L Zn2+
  • Sufficient for250 determinations
  • Shelf lifeat least 3 years after production
  • Sea water suitability: yes, after dilution (1+9)

NANOCOLOR Standard test Chloride

Picture of NANOCOLOR Standard test Chloride
1178178
91820
MN/91820

£91.37 (exc. VAT)
£109.64 (inc. VAT)
Qty
Order now for 7 day delivery
DescriptionMediaReviews
Photometric determination with mercury(II) thiocyanate and iron(III) nitrate.
Chloride ions react with mercury(II) thiocyanate to form undissociated mercury(II) chloride. The liberated thiocyanate forms with iron(III) ions a blood-red colouration.
Reaction basis analog to DIN EN ISO 15682-D31

Data
  • REF918 20
  • Typestandard test 1-20
  • Range0.2 - 125 mg/L Cl-
  • Sufficient for250 determinations*
  • Shelf life1 year
  • Sea water suitability: no

NANOCOLOR Standard test Sulphide

Picture of NANOCOLOR Standard test Sulphide
1178179
91888
MN/91888

£158.27 (exc. VAT)
£189.92 (inc. VAT)
Qty
Order now for 7 day delivery
DescriptionMediaReviews
Photometric determination as methylene blue. N,N-Dimethyl-1,4-phenylene diamine reacts with hydrogen sulfide to form a compound which changes to leucomethylene blue.
This compound is oxidised to methylene blue using iron(III) ions.

Data 
  • REF918 88
  • Typestandard test 1-88
  • Range0.01 - 3.0 mg/L S2-
  • Sufficient for250 determinations*
  • Shelf life3 years
  • Sea water suitability: yes**
* Maximum number, the actual number of tests depends on the sample volume
** Please read the leaflet

NANO Standard test Phenol

Picture of NANO Standard test Phenol
1178180
91875
MN/91875

£124.54 (exc. VAT)
£149.45 (inc. VAT)
Qty
Order now for 7 day delivery
DescriptionMediaReviews
Photometric determination with diazotized 4-nitroaniline. Phenol reacts with diazotised 4-nitroaniline to form a red dye.
The color can fluctuate between yellow, brown and red with other phenols. In addition to phenol most phenol derivatives are determined, too.

Data
  • REF918 75
  • Typestandard test 1-75
  • Range0.01 - 7.0 mg/L Phenol
  • Sufficient for500 determinations*
  • Shelf life3 years
  • Sea water suitability: yes**
* Maximum number, the actual number of tests depends on the sample volume
** Please read the leaflet

NANOCOLOR Standard test Chlorine

Picture of NANOCOLOR Standard test Chlorine
1178181
91816
MN/91816

£78.46 (exc. VAT)
£94.15 (inc. VAT)
Qty
Order now for 7 day delivery
DescriptionMediaReviews
Photometric determination of free and total chlorine with N,N-diethyl-1,4-phenylene diamine (DPD).
Free chlorine, total chlorine and ozone react with DPD N,N-diethyl-1,4-phenylene diamine) to form a red-violet dye. By defined addition of iodide ions, one can differentiate between the individual components.

Data
  • REF91816
  • Typestandard test 1-16
  • Range0.02 - 10.0 mg/L Cl2
  • Sufficient for250 determinations*
  • Shelf life3 years
  • Sea water suitability: yes**
* Maximum number, the actual number of tests depends on the sample volume
** Please read the leaflet

NANOCOLOR Standard test Hydrazine

Picture of NANOCOLOR Standard test Hydrazine
1178182
91844
MN/91844

£73.02 (exc. VAT)
£87.62 (inc. VAT)
Qty
Order now for 7 day delivery
DescriptionMediaReviews
Photometric determination with 4-dimethylaminobenzaldehyde. In acidic solution hydrazine reacts with 4-dimethylaminobenzaldehyde to form a yellow-orange compound.

Data and ordering information
  • REF91844
  • Typestandard test 1-44
  • Range0.002 - 1.50 mg/L N2H4
  • Sufficient for250 determinations
  • Shelf life1 year
  • Sea water suitability: yes*

NANOCOLOR Silver 3 tube test range: 0.20-3.00 mg/L Ag+ 20 Tests

Picture of NANOCOLOR Silver 3
1222795
985049
MN/985049

£62.22 (exc. VAT)
£74.66 (inc. VAT)
Qty
Order now for 9 day delivery
DescriptionReviews

Silver ions react with an indicator to form a blue dye. Insoluble silver compounds like silver bromide, silver chloride, silver iodide, silver cyanide or silverthiocyanate are not detected with this test. These compounds can be determined after pretreatment with NANOCOLOR® NanOx Metal (Cat. No. 918 978).

Data
  • Reference Code: 985049
  • Type: 0.20 - 3.00 mg/l Ag
  • Sufficient for: 20 determinations
  • Shelf life: at least 1.5 years
  • Sea water suitability:

NANOCOLOR Cadmium (without CCl4) Standard test (additionally carbon tetrachloride is necessary)

Picture of NANOCOLOR Cadmium (without CCl4) Standard test (additionally carbon tetrachloride is necessary)
1222729
918131
MN/918131

£116.55 (exc. VAT)
£139.86 (inc. VAT)
Qty
Order now for 9 day delivery
DescriptionMediaReviews

NANOCOLOR Chlorine dioxide standard test range: 0.04-4.00 mg/L ClO2 50 Tests

Picture of NANOCOLOR Chlorine dioxide 4
1222730
918163
MN/918163

£96.15 (exc. VAT)
£115.38 (inc. VAT)
Qty
Order now for 9 day delivery
DescriptionMediaReviews
Photometric determination of chlorine components with N,N-diethyl-1,4-phenylene diamine (DPD). Chlorine dioxide reacts with DPD to form a redviolet dye.

Data:

  • REF: 918 163 T
  • Typestandard test 1-163
  • Range0.04 - 4.00 mg/L ClO2
  • Sufficient for50 determinations*
  • Shelf life1.5 years Sea water suitabilityyes**


* Maximum number, the actual number of tests depends on the sample volume
** Please read leaflet

NANOCOLOR Chromate standard test range: 0.01-3.0 mg/L Cr(VI)

Picture of NANOCOLOR Chromate standard test range: 0.01-3.0 mg/L Cr(VI)
1222731
91825
MN/91825

£75.95 (exc. VAT)
£91.14 (inc. VAT)
Qty
Order now for 9 day delivery
DescriptionMediaReviews
Photometric determination with diphenylcarbazide. In acidic medium, chromate ions react with diphenylcarbazide to form a red-violet colour complex. Chromium(III) ions are not determined unless they are converted to Cr(VI) by silver-catalysed oxidation with ammonium peroxodisulphate/ sulphuric acid. Reaction basis analog DIN EN ISO 18412

Data:

  • Cat. No.918 25
  • Typestandard test 1-25
  • Range10 mm cuvette: 0.1 - 6.0 mg/l CrO42- / 0.1 - 3.0 mg/l Cr(VI) 50 mm cuvette: 0.01 - 1.00 mg/l CrO42- / 0.01 - 0.45 mg/l Cr(VI)
  • Sufficient for250 determinations
  • Shelf life: at least 2 years 
  • Sea water suitabilityyes

NANOCOLOR Cyanide standard test range: 0.001-0.50 mg/L CN- 250 Tests

Picture of NANOCOLOR Cyanide standard test range: 0.001-0.50 mg/L CN-  250 Tests
1222732
91830
MN/91830

£154.02 (exc. VAT)
£184.82 (inc. VAT)
Qty
Order now for 9 day delivery
DescriptionMediaReviews
Photometric determination with barbituric acid/pyridine. Cyanide ions react with chloroamine T to form cyanogen chloride which, with a pyridine derivative and barbituric acid forms a polymethine dye. The test measures free cyanide and cyanide complexes which can be destroyed with chlorine.

Data:
  • REF918 30
  • Typestandard test 1-30
  • Range0.001 - 0.50 mg/L CN-
  • Sufficient for250 determinations*
  • Shelf life1 year
  • Sea water suitability: yes**
* Maximum number, the actual number of tests depends on the sample volume
** Please read the leaflet

NANOCOLOR Detergents anionic Standard test

Picture of NANOCOLOR Detergents anionic Standard test
1222733
91832
MN/91832

£172.70 (exc. VAT)
£207.24 (inc. VAT)
Qty
Order now for 9 day delivery
DescriptionMediaReviews
Data:
  • Ref: 91832
  • Type: standard test 1-32
  • Range: 10 mm cuvette: 0.1 - 5.0 mg/l MBAS, 50 mm cuvette: 0.02 - 1.00 mg/l MBAS
  • Sufficient for: 40 determinations
  • Shelf life: at least 3 years
  • Sea water suitability: no

NANOCOLOR Detergents cationic Standard test

Picture of NANOCOLOR Detergents cationic Standard test
1222734
91834
MN/91834

£172.70 (exc. VAT)
£207.24 (inc. VAT)
Qty
Order now for 9 day delivery
DescriptionMediaReviews
Data:
  • Ref: 918 34 
  • Types: standard test 1-34 
  • Range: 10 mm cuvette: 0.2 - 5.0 mg/l CTAB,  50 mm cuvette: 0.05 - 3.00 mg/l CTAB 
  • Sufficient for: 40 determinations 
  • Shelf life: at least 3 years 
  • Sea water suitability: no

NANOCOLOR Cobalt standard test range: 0.002-0.70 mg/L Co2+ 250 Tests

Picture of NANOCOLOR Cobalt standard test range: 0.002-0.70 mg/L Co2+  250 Tests
1222735
91851
MN/91851

£65.75 (exc. VAT)
£78.90 (inc. VAT)
Qty
Order now for 9 day delivery
DescriptionMediaReviews
At a pH > 5 cobalt(II) ions react with 4-[5-chloropyridyl-(2)-azo]-m-phenylene diamine (5-Cl-PADAB) to form a pink color complex which, contrary to other heavy metal complexes, is also stable below pH 5.

Data 
  • REF91851
  • Typestandard test 1-51
  • Range0.002 - 0.70 mg/L Co2+
  • Sufficient for250 determinations*
  • Shelf life2 years
  • Sea water suitability: yes**
* Maximum number, the actual number of tests depends on the sample volume
** Please read the leaflet

NANOCOLOR Silica Standard Test

Picture of NANOCOLOR Silica Standard Test
1201508
91848
MN/91848

£100.75 (exc. VAT)
£120.90 (inc. VAT)
Qty
Order now for 7 day delivery
DescriptionMediaReviews
Photometric determination as silico-molybdenum blue. in acidic solution dissolved silica and silicates react with ammonium molybdate to form yellow silicomolybdic acid. This is reduced to a blue compound by addition of a reducing agent.
Reaction basis analog to DIN EN ISO 16264-H57

Data
  • REF: 91848
  • Typestandard test 1-48
  • Range0.005 - 10.0 mg/L SiO2 0.002 - 5.0 mg/L Si
  • Sufficient for250 determinations
  • Shelf lifeat least 3 years
  • Sea water suitabilityyes

NANOCOLOR Manganese standard test range: 0.01-10.0 mg/L Mn 250 Tests

Picture of NANOCOLOR Manganese 10
1222738
91860
MN/91860

£142.60 (exc. VAT)
£171.12 (inc. VAT)
Qty
Order now for 9 day delivery
DescriptionMediaReviews
Photometric determination of total manganese with formaldoxime.
In alkaline solution, manganese ions react with formaldoxime to form an orange-red complex.

Data 
  • Cat. No.91860
  • Typestandard test 1-60
  • Range10 mm cuvette: 0.1 - 10.0 mg/l Mn 50 mm cuvette: 0.01 - 2.00 mg/l Mn
  • Sufficient for250 determinations
  • Shelf lifeat least 3 years
  • Sea water suitability: yes

NANOCOLOR Nickel standard test range: 0.01-10.0 mg/L Ni2+ 250 Tests

Picture of NANOCOLOR Nickel standard test range: 0.01-10.0 mg/L Ni2+  250 Tests
1222739
91862
MN/91862

£78.97 (exc. VAT)
£94.76 (inc. VAT)
Qty
Order now for 9 day delivery
DescriptionMediaReviews
Photometric determination with dimethylglyoxime.
In alkaline solution nickel ions react with diacetyldioxime after oxidation to form a red-brown dye.

Data 
  • Cat. No.918 62
  • Typestandard test 1-62
  • Range10 mm cuvette: 0.1 - 10.0 mg/l Ni2+ 50 mm cuvette: 0.01 - 2.00 mg/l Ni2+
  • Sufficient for250 determinations
  • Shelf lifeat least 2 years
  • Sea water suitability: yes, after dilution (1:10)

NANOCOLOR Ozone Standard test

Picture of NANOCOLOR Ozone Standard test
1222744
91885
MN/91885

£74.74 (exc. VAT)
£89.69 (inc. VAT)
Qty
Order now for 9 day delivery
DescriptionMediaReviews
Photometric determination with blue indigo trisulfonate.
The photometric determination of ozone is based on blue indigo trisulfonate. Ozone discolors the indigo compound. The discoloration of the blue dye is determined photometrically.
The test kit is specific for ozone. Chlorine up to 3 mg/L does not interfere the measurement.

Data
  • REF918 85
  • Type: Standard test 1-85
  • Range10 mm cuvette: 0.10 - 1.50 mg/L O3 50 mm cuvette: 0.01 - 1.00 mg/L O3 16 mm cuvette: 0.05 - 1.50 mg/L O3 (only PF-12 and PF-12Plus)
  • Sufficient for200 determinations
  • Shelf lifeat least 1 year from production at 2 - 8 °C
  • Sea water suitability: yes

NANOCOLOR Chlorine dioxide 5 tube test range: 0.15-5.00 mg/L ClO2 20 Tests

Picture of NANOCOLOR Chlorine dioxide 5
1222773
985018
MN/985018

£52.32 (exc. VAT)
£62.78 (inc. VAT)
Qty
Order now for 9 day delivery
DescriptionMediaReviews

Photometric determination of chlorine dioxide with N,N-diethyl-1,4-phenylene diamine (DPD) Reaction basis according to DIN 38408-G5: Chlorine dioxide, like chlorine, reacts with DPD to form a redviolet dye. By using a special supplementary reagent (already included in the test kit), chlorine dioxide is determined selectively.

Data
  • Reference Code: 985018
  • Type: 0.15 - 5.00 mg/L ClO2
  • Sufficient for: 20 determinations
  • Shelf life: at least 1 year
  • Sea water suitability:

Product tags
Related Instruments

Tell us how we are doing and win an AMAZON ECHO SHOW Speaker

 

picWe would appreciate your feedback.