The method used by the 926 chloride meter is based on a coulometric titration and is an absolute method where silver ions are generated at the time of analysis by passing a constant current between donor electrodes. The end point is detected by the use of sensing electrodes which measure the change in solution conductivity which occurs when excess silver ions are present in solution. This coulometric method is very robust and versatile.
This microprocessor based Instrument is ergonomically designed and easy to use and maintain.
Supplied with printer cable, RS232, acid buffer, standard, 3 anodes, set of electrodes, 2 marked beakers, electrode cleaning polish, stirrer and manual.
Instrument Model | 926 |
Application | Industrial |
Units | mg/l |
Sample size | 500μl |
Readout Range | 10- 999 mg/l 2-165 mg% Salt |
Accuracy | ±3 mg/l at the 200 mg/l level |
Reproducibility | CV < 1% for 20 replicate samples @ 200 mg/l (excluding pipetting errors) |
Measurement time | 36 seconds to 200 mg/l |
Voltage (Mains adapter input) | 100 - 240V ~, 50 – 60 Hz, 0.6A |
Size | 315 mm x 200 mm x 250 mm |
Packed Size | 385 mm x 370 mm x 450 mm |
Net Weight | 1.9 kg |
Gross Weight | 5.4 kg |
Packed unit contains | Model 926, Printer cable 9 way RS232, Buffer (500 ml), 200mg/l standard (100ml), 1 pack of anodes, 1 pack of electrodes, 2 marked beakers, Silver Electrode Polish, Stirrer, Operator Manual, Universal Mains adapter and USB lead A(M) – B(M) |
Have you considered your servicing requirements? Much like a car, scientific instruments may need a bit of care to keep them working reliably and at their most accurate.
The Camlab Service Department have over 60 years experience in scientific instrumentation. We have a number of highly qualified internal and field-based service engineers able to perform a variety of jobs including preventative maintenance servicing and calibration.
Camlab can offer yearly service contracts which include two main types of preventative maintenance/calibration services – the back to base service and an engineer visit to your site. These options are can be offered with differing turn around times depending on the instrument type and your requirements along with loan instruments if available.
A typical preventative maintenance service includes the following: Inspection and testing of the unit
Dismantling, cleaning and inspection of the key parts
Correction of minor defects including adjustments if necessary
Reassembly and testing
Take post adjustment / cleaning readings
Supply of calibration certificate
Return of the item to you (back to base services)
|
Request a quote for your servicing requirements today.
For more information on this product please click the Request information button below and we will get back to you as soon as we can. |
Request information |
Alternatively, a consultation visit from one of our highly experienced product specialists is available for this range. Typically our specialist will be able to go through the following aspects with you to help you make the right choices and be able to deliver them on time and and on budget.
|
Request Consultation |
The links above will take you to our request information page which will forward your enquiry to our team. Please provide as much detail as possible so that we can get back to you with the right information. We normally aim to get back to you same day or within 24 hours on weekdays. If you enquiry is more urgent please call our support team on 01954 233 120 |
Related Products
Check items to add to the cart