This device are equipped with up to 34 test methods and a memory for up to 1000 data sets. The PM 630 offers a Bluetooth® interface instead of infrared data transmission. Intuitive operation and a backlit display make this series particularly user-friendly.
The kit contains:
Optics | LEDs, interference filters (IF) and photo sensor in transparent sample chamber |
Wavelength Accuracy | ± 1 nm |
Photometric Accuracy | 2 % FS (T = 20 °C – 25 °C) |
Operation | Acid and solvent resistant, touch-sensitive keypad with audible feedback via integrated beeper |
Display | Graphic-display |
Suitable Vials | Round Cuvettes 24 mm |
Interfaces | Bluetooth |
Internal Storage | approx. 500 data sets |
Power Supply | 4 batteries (Mignon AA/LR6) |
Battery Life Time | approx. 26 h |
Auto – OFF | Yes |
Beeper | existing |
Portability | Benchtop |
Environmental Conditions | 5 – 40 °C at max. 30 – 90 % Conditions rel. humidity (non condensing) |
Compliance | CE |
Protection Class | IP 68 |
Languages User Interface | German, English, French, Italian, Spanish, Portuguese, Polish, Indonesian |
Dimensions | 95 x 45 x 210 mm |
Weight | 450 g |
An important point to note apart from the table below please consult.
Parameter | Â | UK Recommended Levels |
Bromine | Â |
4-6 mg/L |
Calcium Hardness | Â |
80 – 200 mg/L |
Chlorine (Free and Total) |  |
|
Cyanuric Acid | Â |
|
pH | Â |
|
Phosphate |  | 0.01 mg/L or below. |
Total Alkalinity |  | 80 – 200 mg/L CaCO3 |
Turbidity |  | 0.5 NTU (Nephelometric Turbidity Units) |
Parameter | Â | UK Recommended Levels |
Chlorine | Â | 1.0 mg/L |
Bromine | Â | 4-6 mg/L |
PHMB | Â | 20-40 mg/L |
Hydrogen Peroxide | Â | 30-100 mg/L |
Ozone | Â | 1 mg/L for two minutes |
pH | Â | 7.2-7.4 ideally, 7.0-7.6 is acceptable |
Alkalinity | Â | Between 80-200 mg/L |
Cyanuric Acid | Â | 25-50 mg/L |
Calcium Hardness | Â | Below 80-200 mg/L |
Phosphate | Â | Below 0.01 mg/L |
TDS | Â | Not more than 1000 mg/L above mains water, to a maximum of 3000 mg/L |
Salinity | Â | Between 2500-3500 mg/L |
Turbidity | Â | Less than 0.5 NTU |
Colony Count | Â | Not more than 10 CFU per 100 mL |
Total Coliforms | Â | Absent in 100 mL |
E. coli |  | Absent in 100 mL |
Ps. Aeruginosa | Â | Absent in 100 mL |
Have you considered your servicing requirements? Much like a car, scientific instruments may need a bit of care to keep them working reliably and at their most accurate.
The Camlab Service Department have over 60 years experience in scientific instrumentation. We have a number of highly qualified internal and field-based service engineers able to perform a variety of jobs including preventative maintenance servicing and calibration.
Camlab can offer yearly service contracts which include two main types of preventative maintenance/calibration services – the back to base service and an engineer visit to your site. These options are can be offered with differing turn around times depending on the instrument type and your requirements along with loan instruments if available.
A typical preventative maintenance service includes the following: Inspection and testing of the unit
Dismantling, cleaning and inspection of the key parts
Correction of minor defects including adjustments if necessary
Reassembly and testing
Take post adjustment / cleaning readings
Supply of calibration certificate
Return of the item to you (back to base services)
|
Request a quote for your servicing requirements today.