SAMPLING & SAMPLE PREPARATION - Which sample? Which User?
- Traceability right from the start
- RFID encoding of each sample
- Reliable identification of samples
- Assured traceability of samples
- RFID data transfer from the sample to the spectrophotometer
Samples must be traceable to generate reliable results in the field of water analysis. RFID uses contactless data transfer to guarantee reliable identification of samples.
The user when taking a sample is able to transfer sample location, date, time and sample taker information to the bottle. The bottle is then scanned on the instrument to transfer data to the instrument.
Compatible with the full range of Hach LCK vials in 13mm format
PREVENT MEASUREMENT ERRORS - Trust in your results
With the new 2D barcode on our cuvettes, the DR 3900 photometer automatically identifies from whether there is a new cuvette test available or if an existing method needs to be updated. If so, the required calibration data is now directly available from the RFID tag on the cuvette packaging. The The 2D barcode contains batch number and expiry date details of the reagents. If the expiry date has already passed. Automatic alerts warn of expiry dates and if there are any discrepancies in the C:N:P ratio and if any thresholds are exceeded
TRANSPARENT ANALYSIS - Real-time communication between lab and process with LINK2SC
The LINK2SC connection between the photometer and an SC controller guarantees that analysis is transparent, facilitating direct comparison between laboratory and process results. The data from the laboratory is returned to the controller via Ethernet and the process probe is adjusted (where necessary).
- Easy adjustment of lab and process data with LINK2SC
- Bi-directional data streams
- If necessary, immediate matrix correction of the process probe
AQA measurements can now be defined and documented in the spectrophotometer itself. Current batch certificates (for GMP/GLP documentation purposes) can be found on the RFID tag of the cuvette test packaging. They can be retrieved immediately on the DR 3900 photometer and printed out. Measurement values are saved using the established ADDISTA system with standard and round robin solutions. Quality control cards can now be created and maintained in the spectrophotometer.
COMMUNICATION & DOCUMENTATION - Data transfer via Ethernet connection or USB stick
The DR 3900 Spectrophotometer can be networked, supporting the efficient documentation of analysis data in various connected systems. The spectrophotometer also helps to make sure that measurement values are correctly interpreted and classified.
The DR 3900 delivers comprehensive reliable water analysis results at every stage of the water analysis process.
Have you considered your servicing requirements? Much like a car, scientific instruments may need a bit of care to keep them working reliably and at their most accurate.
The Camlab Service Department have over 60 years experience in scientific instrumentation. We have a number of highly qualified internal and field-based service engineers able to perform a variety of jobs including preventative maintenance servicing and calibration.
Camlab can offer yearly service contracts which include two main types of preventative maintenance/calibration services – the back to base service and an engineer visit to your site. These options are can be offered with differing turn around times depending on the instrument type and your requirements along with loan instruments if available.
A typical preventative maintenance service includes the following: Inspection and testing of the unit
Dismantling, cleaning and inspection of the key parts
Correction of minor defects including adjustments if necessary
Reassembly and testing
Take post adjustment / cleaning readings
Supply of calibration certificate
Return of the item to you (back to base services)
|
Request a quote for your servicing requirements today.
The DR1900 by Hach is a portable spectrophotometer with over 220 pre-programmed test methods, accepting the Hach and the Lange chemistry. It is rugged and has a large, clear screen, with easy to use navigation, making it great for use in the field. [caption id="attachment_15657" align="aligncenter" width="300"] The DR1900 portable spectrophotometer[/caption] The DR1900 will accept the followi...
The DR900 by Hach is a robust, portable colorimeter, capable of performing many dozens of different tests, supporting the Hach chemistry type. It can accept a number of different sizes cuvettes/samples cells – 1 inch round sample cells 1cm sample cells 16mm COD/TNT vials [caption id="attachment_15641" align="aligncenter" width="300"] Hach DR900 colorimeter[/caption] Every Hach method c...
Hach have a wide variety of sample cells for use in their colorimeters and spectrophotometers. The correct type of sample cell that is required for every method programme with each compatible instrument will be detailed at the start of the method sheet. Here, any adapters that may be required along with any extra equipment needed to perform the test will also be listed. This is the typical form...
A.Trying to pick out the correct test can prove to be a challenge. There are a number of different tests available from Hach to test for Iron and you will need to select the most appropriate test for the specific form of iron you are testing for. Iron can be present in natural and treated water. The presence of excess iron can have negative impacts for instance insoluble deposits (rust) can ...
Total organic carbon (TOC) is the amount of carbon found in an organic compound and is an important sum parameter for accessing the organic load of water. As all organic carbon compounds are determined and specified in terms of carbon mass, TOC is an exactly definable absolute quantity and is directly measurable (unit: mg/L C). On its own TOC sheds no light on the oxidisability of the me...
Spectrophotometers are relied on by a wide range of laboratories, for tests ranging from specific parameters, like chlorine or metals concentrations, right through to complex analyses of reaction kinetics. When choosing a spectrophotometer the range of specifications and price is vast, so take the time to list the features you need before you buy and make sure you choose the right one. [c...
The pocket colorimeter kit by Hach offers an immunoassay method to measure TPH (Total Petroleum Hydrocarbons) in soil samples - a useful indicator of petrol pollution or contamination in soil. For areas of heavy contamination the range of the test can be extended by dilution during the soil extraction step. [caption id="attachment_7251" align="aligncenter" width="300"] Soil Testing for co...
The new Hach Dr3900 spectrophotometer replaces the popular Hach DR2800 spectrophotometer. The DR 3900 employs the latest RFID(Radio Frequency Identification) technology to ensure that an accurate, reliable, traceable record is created for every sample. Eliminating potential errors: Small changes are sometimes made to analytical methods and these...
Total Petroleum Hydrocarbons (TPH) is a term used for any mixture of hydrocarbons that are found in crude oil. The presence and concentration of total petroleum hydrocarbons, as well as oil and grease, in domestic and industrial wastewater is of concern to the public because of its deleterious aesthetic effect and its impact on aquatic life. Regulations and standards have been establi...
Related Products
Check items to add to the cart
XD 7000 Vis Spectrophotometer for Potable, Waste and Process Water Testing
Â
£5,407.12 excl. VAT
£6,488.54 inc. VAT