The Genova Bio is a simple, low cost, easy to use UV/visible spectrophotometer dedicated for life science applications. It is compatible with a wide range of small volume cuvettes, making it ideal for measuring DNA and RNA samples. To make measurements quicker and easier, the Genova Bio has pre-programmed methods for the measurement of nucleic acid concentration and purity, protein assays and cell density. This spectrophotometer measures across a UV/visible wavelength range of 198 to 800nm, with a narrow spectral bandwidth of 3nm. The Genova Bio is covered by a two-year warranty which includes the xenon lamp.
Pre-programmed modes:
Nucleic acids:
The Nucleic Acids measurement mode can be used to quantify the concentration and purity of dsDNA, ssDNA, RNA and oligonucleotides; using wavelengths recorded at 260, 280 and 230nm, with an optional correction at 320nm. The concentration is calculated along with the corresponding ratios. At the touch of a button it is easy to check the purity of the nucleic acids. This is done by identifying distorted peaks in the purity scan between 200 and 350nm. This is especially useful for RNA samples where impurities maybe present at 230nm, but cannot be detected using the 260/ 280nm ratio measurement.
Proteins:
The Proteins measurement mode can be used to calculate protein concentration by creating standard curves from protein assay kits. With pre-programmed methods for measuring Bradford, Lowry, Biuret and Bicinchoninic Acid (BCA) assays; up to 6 standards can be measured with 3 replicates of each standard to minimise any dilution errors.
The Proteins measurement mode is also pre-programmed with the Direct UV and Warburg-Christian methods to determine protein purity.
Cell density:
The Genova Bio has a pre-programmed method for measuring optical density of bacterial cultures such as E.Coli and yeast cells. This is ideal to measure cell growth before cell harvesting.
As well as these pre-programmed methods this versatile spectrophotometer has measurement modes for simple photometrics, concentration, quantitation, spectrum scanning and kinetics. Enabling measurements to be performed at any selected wavelength between 198 to 800nm.
USB Connectivity
There are two USB ports for data storage and printer connectivity. The easy access USB port on the front of the instrument can be used to easily store results and transfer data as tab delimited text files to Microsoft Excel
Accessories:
Technical Specifications:
Wavelength Range | 198 to 800nm |
Wavelength Accuracy | ± 2nm |
Wavelength Repeatability | ± 2nm |
Spectral Bandwidth | 3nm |
Absorbance Range | - 0.300 to 2.500A |
Absorbance Accuracy | ± 0.01A at 1.0A and 546nm |
Absorbance Stability (A) | ± 0.005A/h at 0.04A and 546nm |
Noise | ± 0.002A at 0.04A and ± 0.02A at 2.0A and 546nm |
Stray Light at 340nm, %T | < 1%T according to ANSI/ASTM E387- 72 |
Concentration Range | ± 2500 |
Concentration Calibration | Blank with a single standard or factor |
Concentration Factor | ± 1000 |
Concentration Standard | ± 1000 |
Optical Density Factor | ± 1000 |
Quantitation Range | ± 2500 |
Quantitation Calibration | Blank with up to 6 standards |
Curve Fit Algorithms | Linear and linear through zero |
Kinetics Measurement Time | 7 to 9999 seconds |
Kinetics Number of wavelengths | 3 |
Kinetics Calibration | Blank with a factor |
Kinetics Display | Graphical and concentration |
Kinetics Analysis | Concentration |
Spectrum Range | 198 to 800nm |
Nucleic Acids | Pre-programmed methods for dsDNA,ssDNA,RNA, oligos. Concentration, purity, optioal background correction, spectrum scan |
Proteins | Purified proteins at 280nm and Warburg-Christian. Protein assays (Bradford, Biuret, Lowry, BCA) |
Cell Density | 600nm optical density reading and conversion factors in cells/ml |
Spectrum Analysis | Absorbance or % transmittance and up to 50 spectral analysis points |
Beam Height | 15mm |
Light Source | Xenon Lamp |
Results/Method Memory | Limited by attached USB memory stick |
Removable Media | USB |
Outputs | USB x 2 |
Supply voltage/frequency | 100 - 240VAC at 50 to 60Hz |
Power Supply | 12V DC, 3.8A |
Size (w x d x h) | 212 x 422 x 120mm |
Weight | 2.8kg |
Warranty | 2 years on the instrument, including lamp |
Have you considered your servicing requirements? Much like a car, scientific instruments may need a bit of care to keep them working reliably and at their most accurate.
The Camlab Service Department have over 60 years experience in scientific instrumentation. We have a number of highly qualified internal and field-based service engineers able to perform a variety of jobs including preventative maintenance servicing and calibration.
Camlab can offer yearly service contracts which include two main types of preventative maintenance/calibration services – the back to base service and an engineer visit to your site. These options are can be offered with differing turn around times depending on the instrument type and your requirements along with loan instruments if available.
A typical preventative maintenance service includes the following: Inspection and testing of the unit
Dismantling, cleaning and inspection of the key parts
Correction of minor defects including adjustments if necessary
Reassembly and testing
Take post adjustment / cleaning readings
Supply of calibration certificate
Return of the item to you (back to base services)
|
Request a quote for your servicing requirements today.
For more information on this product please click the Request information button below and we will get back to you as soon as we can. |
Request information |
Alternatively, a consultation visit from one of our highly experienced product specialists is available for this range. Typically our specialist will be able to go through the following aspects with you to help you make the right choices and be able to deliver them on time and and on budget.
|
Request Consultation |
The links above will take you to our request information page which will forward your enquiry to our team. Please provide as much detail as possible so that we can get back to you with the right information. We normally aim to get back to you same day or within 24 hours on weekdays. If you enquiry is more urgent please call our support team on 01954 233 120 |
Spectrophotometers are relied on by a wide range of laboratories, for tests ranging from specific parameters, like chlorine or metals concentrations, right through to complex analyses of reaction kinetics. When choosing a spectrophotometer the range of specifications and price is vast, so take the time to list the features you need before you buy and make sure you choose the right one. [c...
Disposable cuvettes are used in many labs where cross contamination of samples is a concern or where the cost of quartz or glass cuvettes is too high. Some disposable plastic cuvettes are not compatible with many common solvents, but the UV-Cuvette range from Brand offers excellent chemical compatibility, as well as high quality, in a disposable cuvette. [caption id="attachment_7087" alig...