The Grant bio DEN-1B is a compact benchtop densitometer (suspension turbidity meter) for measuring turbidity of cell suspensions in a variety of life science applications.
The Grant DEN-1 and DEN-1B are designed and factory calibrated to measure turbidity in the range of 0.5 to 4.0 McFarland units (DEN-1) 0.0 to >7.5 McFarland units (DEN-1B) with a small standard deviation. If required, it can deliver a wider measurement range (up to 15.00 McFarland units), but with a greater standard deviation.
Life science – typical applications include determining concentration of cells (bacterial and yeast cells) in the fermentation process, detecting the susceptibility of micro-organisms to antibiotics, identifying micro-organisms with various test systems, and measuring optical density at fixed wavelength.
Model |
DEN-1 |
DEN-1B |
Dimensions (h x d x w) | 75 x 115 x 165mm | 75 x 115 x 165mm |
Temperature range | +4 to 40ºC | +4 to 40ºC |
Light source | LED | LED |
Wavelength | 565 ±15Inm | 565 ±15Inm |
Range (McFarland units) | 0.3 to 15.0 | 0.00 to 15.00 |
Precision | ±3% | ±3% |
Measurement time | 1sec | 1sec |
Tube diameter – external diameter | 18mm | 18mm |
Tube diameter – with D16 adapter | 16mm | 16mm |
Sample volume | >2ml | >2ml |
Display/display resolution | LED/0.1 McF | LED/0.1 McF |
Independent power supply | – | 3 x AA batteries |
External Power supply | Input AC 120-230V, 50/60Hz Output DC 12V | Input AC 120-230V, 50/60Hz Output DC 12V |
Power consumption – 230V | 1W (0.08A) | 0.1W (0.007A) |
Power consumption – 120V | ||
Weight | 0.7kg | 0.7kg |
Have you considered your servicing requirements? Much like a car, scientific instruments may need a bit of care to keep them working reliably and at their most accurate.
The Camlab Service Department have over 60 years experience in scientific instrumentation. We have a number of highly qualified internal and field-based service engineers able to perform a variety of jobs including preventative maintenance servicing and calibration.
Camlab can offer yearly service contracts which include two main types of preventative maintenance/calibration services – the back to base service and an engineer visit to your site. These options are can be offered with differing turn around times depending on the instrument type and your requirements along with loan instruments if available.
|
|
A typical preventative maintenance service includes the following: Inspection and testing of the unit
Dismantling, cleaning and inspection of the key parts
Correction of minor defects including adjustments if necessary
Reassembly and testing
Take post adjustment / cleaning readings
Supply of calibration certificate
Return of the item to you (back to base services)
|